Functional disconnection
Unipolar
Safety disconnection
Unipolar
Safety cut-out technology
Bimetallic disk
Safety reset
Manual
Max room temperature
100 °C
Rated current / voltage
16 A / 240 V
Functional temperature (factory setting)
From 50 °C to 90 °C, according to Customer specification
Safety cut-out temperature (factory setting)
From 50 °C to 115 °C, according to Customer specification
Functional temperature hysteresis
8 °C +/- 4 °C
Standard stem lenght
11" (280 mm)
Stem lenght on request
7" (180 mm) / 18" (450 mm)
Electrical connection to heating element
Screw terminals